User login

Download

IPETRONIK LOG M.A.L.-PlugIn V03.18.00

Print Mail
IPETRONIK LOG M.A.L.-PlugIn V03.18.00

Release Notes

___________________________________________________________________________________

Bitte beachten Sie, dass die Release Notes nur in englischer Sprache verfgbar sind.
Veuillez faire attention à ce que les Release Notes sont seulement disponible en anglais.
Please note that the release notes are only available in english language.

Application: IPEmotion MAL-PlugIn IPETRONIK LOG
Last entry: 27.08.2009
Current version: V03.18.00

___________________________________________________________________________________
The distribution of beta versions or release candidates to customers is not enabled without authorization of
the management.

System requirements:

* Screen resolution: min. 1.024 x 600 pixel
* Processor: min. 1 GHz
* RAM: min. 512 MB

Supported platforms:

* Microsoft Windows XP (Service pack 2 or higher)
* Microsoft Windows Vista (only 32 Bit)

The following software will be installed:

* Microsoft .NET 2.0 Framework incl. Language package German and French
* Microsoft MSXML 4.0
* Microsoft Visual C++ 2005 Redistributable
* IPETRONIK LOG2PC core
___________________________________________________________________________________

Rights

IPEmotion MAL-PlugIn IPETRONIK Logger needs administrator rights during installation. Standard user rights
are needed for working with IPEmotion MAL-PlugIn IPETRONIK Logger.
___________________________________________________________________________________

Content

The following points describe the extensions, changes and exception handlings in the corresponding
versions:

V01.00.00

CAUTION: Detect and Initialize are executed on ALL Loggers

Known restrictions:
* No configuration support for M-VIEWgraph and M-VIEWfleet
* No configuration support for Powermanagement
* No configuration support for COMgate
* No parallel use of LOG2PC service and LOG2PC applet possible

V01.01.00

Detect mode selectable between all logers, one logger or logger selection dialog (default)

Known restrictions:
* No configuration support for M-VIEWgraph and M-VIEWfleet
* No configuration support for Powermanagement
* No configuration support for COMgate
* No parallel use of LOG2PC service and LOG2PC applet possible

V03.18.00

New data managenet dialog
COMgate
Powermanagement
M-VIEWgraph and M-VIEWfleet
LIN import
Diagnostic import
External calculations

Known restrictions:
* To use the Logger with XCP service it is necessary to set both IP addresses (PC and Logger) eighter both to DHCP or both to static in the same network area
* CCP measurement: Pure CCP measurement using polling is not supported. There has to be at least one channel with a configured DAQ-list.
* XCP-service: Status channels of an IPETRONIK CAN system can not be send by XCP-service.
* XCP-Service: Floating point signals (e.g. formulas) can not be send by XCP-Service.
* CAN input status signals can not be displayed on M-VIEWgraph or M-VIEWfleet.
* In formulas, the operations asin, acos and atan are not supported.
* In formulas, operations with constant operands only are not supported. E.g. the formula sin(1) is not supported.

Known bugs:
* No undo-funtionality for decimal places
* Detection of a logger using Windows VISTA always results in a logger with 4 CAN-channels, no matter what kind of logger you are using.




Re: IPETRONIK LOG M.A.L.-PlugIn V03.18.00

 

Information about the M-LOG Update:

 

You have to know that for the IPETRONIK LOG M.A.L.-PlugIn V03.18.00 the logger must be have the respective version of Testdrive 3.18.02.

 

The easiest way to do this: select the "Update" button in Tab "extended" in the Logger configuration


Print Mail